❝A Release of Gas❞

Last issue we talked about the critical water shortage in Bali and how much water each of us uses every day. As I said in that article lowering water tables is a serious problem and one that is going to get a lot worse as expanding population and uncontrolled "high water use" luxury development continues apace.

Unfortunately I suspect this tricky situation is about to get a whole lot worse. The cause - the new sewerage system currently being installed around Southern Bali. Certainly this new system will produce considerable improvements to water quality and domestic hygiene but in fact it could well have a devastating effect on our already strained water tables.

As we all know the most of our household waste water goes into septic tanks buried in our gardens. In the septic tank the waste is broken down by natural enzymes and the waste then drains rather haphazardly into the ground. In well administered urban situations the drainage of septic tanks is strictly regulated but in Indonesia no one really knows or cares very much where the drainage goes. This is why there is such an issue with groundwater being contaminated. Of course we then pump this water from our wells and bores for showers and baths and an obvious hazard to our health. I came across a shower only yesterday with a bouquet like a cowboy's saddle.

Under present circumstances the vast majority of our "used" water is being returned to the water table. When the new sewerage system comes on line the vast majority of our waste water will be sent down concrete pipes to a processing plant and from there directly to the sea thereby bypassing the water table.

How serious a problem this becomes we shall just have to wait and see.

Gas cylinders, regulators and hoses have become an ongoing cause of concern for many people. In a recent article we looked at the government issued equipment (and locally made copies), much of which is substandard, have been the cause of a series of explosions and have resulted in a number of public demonstrations. The difficulty is that millions (75 million) have been released to the general public and in a country where many people have to make a living in any way they can, it will be very difficult to withdraw them. They are going to be around for a long time to come.

This is an obvious cause for concern however as long as you use good quality equipment and avoid the small green gas cylinders you should not have a problem.

Inga asks:

"I am frequently visited from sharply dressed young men who say they come from 'Pertamina' - but turn out to represent a private company. They want to check my gas equipment and nearly every time, they find dangerous faults.

Last year, they replaced my standard gas hoses (previously installed by a main electronics shop in Denpasar) with 'safe' hoses that had a mesh woven into them.

They also replaced my standard regulator with a non-leak regulator, where gas does not exit into the gas hose unless you open your gas appliance, so there is no gas pressure standing inside the hose. The young men said such gas pressure in the hose will cause it to deteriorate and leak.

Another pair of sharp looking young men arrived today, declaring that last year's regulator was 'broken' so I had to buy the latest model (with SNI stamp and 5 years guarantee, Ibu).

They also said I had to change my gas hoses again, with their brightly orange coloured type ('with metal mesh inside, Ibu').

I sense something fishy about these keen, young salesmen. At the same time, I am worried about gas safety.

1. Is it dangerous to use a 'normal' gas regulator that lets gas flow into the gas hose at all times?
2. What type of gas hose must I use?
3. How often do gas hoses and regulators generally need changing?
4. One of my gas hoses, which receives direct sunlight in the afternoon, looks 'cracked'. It looks a bit like an old bicycle tyre - dry, brittle and cracked into a marble pattern. Should it be changed?"

 

Yes Inga as fishy as Neptune's naughty bits! You should always be wary of smart young men wanting to check out your equipment.

These young men, always in pairs, sometimes in uniforms and very often carrying an official "identification", are in fact fraudsters. I had a couple came to my house and let them in just so I could watch how they operate and hear what they said. The comments they made about my existing regulator were like something from the Mad Hatter's teaparty, words invented to persuade me to buy a new regulator - from them of course. In answer to your questions:

1 All gas regulators allow gas into the hose at the standard low pressure that is required for your cooker. The "safe" type they are talking about is simply not possible. You should always look for the "SNI" (Indonesian Standards) mark on the regulator but bear in mind that this is Indonesia and anyone can put SNI on their product.

2 There are various types of hose around, don't use the thin plastic ones. Look at the end of the hose to see how it is made. I tend to look for thick rubber ones with a canvas reinforcing layer in the centre of the rubber. Check that the rubber is in good condition all the way along and that at the ends the layers have not come apart. Safety hoses tend to have a metal spiral wrapping to protect the rubber from damage but have a downside in that you cannot inspect the condition of the rubber underneath.

3 A good regulator may last for years without problem. I have had the same hose and regulator on my cooker for 6 years now. Problems are usually found in the hose and the rubber seal in the top of the gas cylinder.

4. Yes Inga, if there are any signs of cracking in the rubber replace the hose as soon as possible.

In a letter from Adam he quite rightly points out that the most dangerous aspect of using gas cylinders is the need to move the regulator from one gas cylinder to another. This is the time when mistakes and problems occur particularly when carried out by the pembantu.

The regulator is installed fitting inside a small rubber sealing ring which is fitted inside the top of the brass valve on the top of the gas cylinder. This seal often becomes damaged and doesn't seal properly. Pertamina usually make sure that the seal is in good condition when they refill cylinders but you should always be careful.

When installing a regulator:

Firstly make sure that the seal is in good condition. If it isn't in good condition gently remove it making sure you don't damage the brass valve that the seal fits into. Install a new one (new seals are available from a number of places including hardware shops and it is good to always keep a few handy) making sure it is properly seated in the groove in the top of the brass valve.

Check the regulator is clean and in good condition. Turn the plastic knob on the side of the regulator and check that it is working correctly. As you turn the knob you should see a clamp move up inside the end of the regulator and then a pin come out from the bottom. The clamp pulls the regulator onto the valve and holds it in place while the pin pushes down into the brass valve to release the flow of gas. Turn the knob back to its "open" position with the pin withdrawn.

Carefully push the regulator onto the top of the brass valve, hold it down and turn the plastic knob. Do not force anything. If the knob doesn't turn find out why. If the regulator installs correctly you may hear a short hiss or pop as the gas is released. This initial flow will push the seal into position sealing the regulator to the valve and the hiss should stop.

Listen carefully, if the regulator is correctly installed you should not hear any hissing. If the seal is leaking you will probably hear a gentle hissing noise. If the regulator doesn't seal remove it and check the condition of the rubber sealing ring and also the outer surface of the bottom of the regulator against which the seal must seat.

And finally this week examination of some recent PLN bills reveals - very little I'm afraid. Trying to track down exactly how new bills are being calculated is proving rather elusive. I'll let you know when we get to the bottom of it so to speak.

Phil Wilson

Copyright © Phil Wilson 2009
This article or any part of it cannot be copied or reproduced without permission from the copyright owner.

Air Conditioners - introduction
divider
Air Conditioners - inverter
divider
Air Conditioner - refrigerants
divider
Air Con. Water Heaters
divider
Architecture - unsafe design
divider
Attitude
divider
Architectural Blindspots
divider
Boundary Walls
divider
Building - a checklist
divider
Building costs
divider
Building local permission
divider
Building Properly
divider
Building permits IMB
divider
Buying Property
divider
Buying Property with care
divider
Carpets
divider
Ceiling Fans
divider
Chimneys and flues
divider
Concrete roof sealing
divider
Corrosion and rust
divider
Cracks in buildings
divider
Cyclones and Hurricanes
divider
Cyclones - house protection
divider
Dampness in walls
divider
Disabled Access
divider
Drainage
divider
Design Quality - condotels
divider
Earthquakes introduction
divider
Earthquakes and building
divider
Earthquakes and design
divider
Earthquake risk in Bali
divider
Earthquake checking for damage
divider
Electricity bill introduction
divider
Electricity bill calculation
divider
Electricity bill update
divider
Electricity contracts
divider
Electricity - earth connections
divider
Electricity high consumption
divider
Electricity - how to save 1
divider
Electricity - how to save 2
divider
Electrical power savers
divider
Electricity safe installation
divider
Electricity safety
divider
Electricity stealing
divider
Electricity supply problems 1
divider
Electricity supply problems 2
divider
Electricity voltage regulators
divider
Electro magnetic radiation
divider
Float valves
divider
Floor tiles
divider
Foundations
divider
French door design
divider
French door design faults 2
divider
Gas cylinder safety 1
divider
Gas cylinder safety 2
divider
Dangerous gas equipment
divider
Gas water heaters
divider
Generators
divider
Holes in pavements
divider
Insurance for buildings
divider
Land certificates
divider
Land access
divider
Land access problems
divider
Land prices
divider
Leaky concrete roofs
divider
Leaking windows
divider
Light bulbs - halogen spots
divider
Maintenance and Balinese attitude
divider
Minimalist Architecture
divider
Mosquitoes
divider
Nuclear Reactors
divider
Nuclear Power - risks
divider
Paint coatings - a primer
divider
Painting walls and masonry
divider
Painting house walls
divider
Planned Obsolescence
divider
Plumbing quality of fittings
divider
Plumbing - smelly drains
divider
Project Management
divider
Property values
divider
Quality
divider
Quantity Surveying
divider
Rabies
divider
Rats
divider
Reinforced concrete
divider
Renovation 1 Tired Buildings
divider
Renovation 2 How to Approach
divider
Renting out your property
divider
Roofs - general
divider
Roofs gutters
divider
Roofs - leaking
divider
Roofs - low cost materials
divider
Roofs - Polycarbonate
divider
Roof venting & insulation
divider
Standards SNI
divider
Screw Threads
divider
Sensors
divider
Septic and sewerage
divider
Septic tank design
divider
Blocked toilets
divider
Solar water heaters
divider
Soil tests
divider
Steel
divider
Stainless Steel
divider
Swimming pools 1
divider
Swimming pools 2
divider
Swimming pool pump rooms
divider
Termites
divider
Termites - have I got them?
divider
Termites - anti termite systems
divider
Terrazzo
divider
Toilets
divider
Traditional wooden houses
divider
Trees
divider
Trusting Technology
divider
Wall linings
divider
Water and Bali Belly
divider
Water contamination
divider
Water heaters - Air Con
divider
Water heaters - electric
divider
Water heaters - gas
divider
Water heaters - solar
divider
Water - hard water
divider
Water meter and leaks
divider
Waterproofing walls
divider
Water pressure tanks
divider
Water pressure problems
divider
Waterpumps
divider
Waterpumps - how big?
divider
Water systems
divider
Water tables and shortages
divider
Water shortage 2
divider
Water tanks
divider
Water testing
divider
Water usage
divider
Building construction and Project Management